電站測溫(wēn)用熱電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程(chéng)規格
名稱(chēng)
|
分度號
|
測溫範圍℃
|
精度(dù)等級
|
允差Δt
|
鎳鉻-鎳(niè)矽(guī)熱電偶
|
K
|
0~800
|
2
|
±2.5℃或(huò) ±0.75%t
|
鎳(niè)鉻-銅鎳熱電偶
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注:t為感溫元件實測溫度或實測溫度的絕對值。
□公稱壓力
一般是指在(zài)常溫下,保護(hù)管所能(néng)承受的靜態外壓而不破裂,試驗(yàn)壓力一般采用(yòng)公稱壓力的1.5倍。實(shí)際上,允許工作壓力不僅(jǐn)與保護管材(cái)料、直徑、壁厚有(yǒu)關,而且還與其結構形式、安裝(zhuāng)方法、置入深度(dù)以(yǐ)及被測介質的流速、種類有(yǒu)關。
□熱電偶絕緣電阻
常溫絕緣電阻的試驗(yàn)電壓為直流500V。測量常溫絕緣電阻的大氣條件(jiàn)為:溫度15~35℃,相對濕(shī)度(dù)45%RH,大氣壓力86~106kPa。
對(duì)於長度超過1米的熱電偶,它的常溫絕緣電阻值與其長度的乘積應不小於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的常溫絕緣(yuán)電阻值,MΩ;
L-熱電偶的長度,m。
對於(yú)長度等於或不(bú)足1米的熱電偶,它的常溫絕緣電阻值應不小於100MΩ。
□熱電阻絕緣(yuán)電阻(zǔ)
常溫絕緣電阻的試驗電壓可取直流10~100V任意值,環境溫度應在(zài)15~35℃範圍內,相對濕度應不大(dà)於80%RH,常溫絕緣電阻(zǔ)值應不小於100MΩ。
□熱電阻允(yǔn)許通過電流
通過(guò)鉑電阻的測量電流(liú)最大不超過5mA。
|