電站測溫用(yòng)熱電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程規格
名(míng)稱
|
分度號
|
測溫範圍℃
|
精度等級
|
允差Δt
|
鎳(niè)鉻-鎳矽熱電偶
|
K
|
0~800
|
2
|
±2.5℃或(huò) ±0.75%t
|
鎳鉻-銅鎳熱電偶
|
E
|
0~600
|
2
|
±2.5℃或(huò) ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注:t為感溫元件(jiàn)實測溫度或實測溫(wēn)度的絕對值。
□公稱(chēng)壓力
一般是指在常(cháng)溫下,保護管所能承受的靜態外壓而(ér)不破裂,試驗壓力一般采用公稱壓力的1.5倍(bèi)。實(shí)際上,允許(xǔ)工作壓力不僅與(yǔ)保護管材料、直徑、壁厚有(yǒu)關,而且還與其結構形式、安裝方法、置入深度以及被測介質(zhì)的流(liú)速、種類有關。
□熱電偶絕緣電(diàn)阻
常溫絕緣電阻的(de)試驗電壓為直流500V。測量常溫絕(jué)緣電阻(zǔ)的大氣條件為:溫(wēn)度15~35℃,相對濕度45%RH,大氣壓(yā)力86~106kPa。
對於長度超過1米的熱電偶,它的常溫絕緣電阻值與其長度(dù)的乘積應不小於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的(de)常溫絕緣電阻值,MΩ;
L-熱電偶的長(zhǎng)度,m。
對於長度等(děng)於或不(bú)足1米的熱電偶,它的常溫絕緣電阻值應不小於100MΩ。
□熱電阻絕緣電阻
常溫絕緣電阻的試驗電壓可取直流10~100V任意(yì)值,環境溫(wēn)度應在15~35℃範圍內,相對濕度應不大於80%RH,常溫絕緣電阻值應不(bú)小於(yú)100MΩ。
□熱電阻允許通過電流
通過鉑電阻的(de)測量電流最大不超過(guò)5mA。
|